Electrolyzer for Brine Electrochlorination

Batch Type

.

Batch type 8 hours per day

Capacity Single electrolyzer, having the production capacity of available Cl2per hour is
Minimum size: 6.25 grams 
Maximum size: 125 grams

Concentration

6000 ppm to 8000 ppm of Cl2

Design

PPE, CTE, PP&ME

Polarity

Normal & Reverse
Substrate Titanium sheet / plate as per ASTM B 265 Gr.1
Titanium tube / pipe as per ASTM B 338/337 Gr.1
Titanium expanded mesh as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1

Catalyst

Platinum group precious metal mixed oxides

Application

Disinfection

Replacement

Mac, Siemens, Sal-Chlor & Many more.

.

Batch type 20 hours per day

CapacitySingle electrolyzer, having the production capacity of available Cl2per hour is
Minimum size: 25 grams 
Maximum size: 1000 grams

Concentration

7000 ppm to 8000 ppm of Cl2

Design

PPE

Polarity

Normal and Reverse

Substrate

Titanium sheet / plate as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1

Catalyst

Platinum group precious metal mixed oxides

Application

Disinfection 

.

Portable type 24 hours batch

CapacitySingle electrolyzer, having the production capacity of available Cl2per hour is
Minimum size: 50 grams 
Maximum size: 100 grams

Concentration

6000 ppm to 8000 ppm of Cl2

Design

CTE

Polarity

Normal

Substrate

Titanium sheet / plate as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1

Catalyst

Platinum group precious metal mixed oxides

Application

Disinfection


.

Continuous Type

.

Continuous type without chiller

CapacitySingle electrolyzer, having the production capacity of available Cl2per hour is
Minimum size: 125 grams 
Maximum size: 300 grams

Concentration

5000 ppm to 8000 ppm of Cl2

Design

PPE

Polarity

Normal & Reverse
SubstrateTitanium sheet / plate as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1

Catalyst

Platinum group precious metal mixed oxides

Application

Disinfection & Electro Oxidation

..

Continuous type with chiller

CapacitySingle electrolyzer, having the production capacity of available Cl2per hour is
Minimum size: 400 grams 
Maximum size: 2000 grams

Concentration

7000 ppm to 8000ppm of Cl2

Design

PPE, CTE, PP&ME

Polarity

Normal & Reverse
SubstrateTitanium sheet / plate as per ASTM B 265 Gr.1 
Titanium tube / pipe as per ASTM B 338/337 Gr.1
Titanium expanded mesh as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1

Catalyst

Platinum group precious metal mixed oxides

Application

Disinfection

.

Continuous type with chiller Normal polarity

CapacitySingle electrolyzer, having the production capacity of available Cl2per hour is
Minimum size: 3000 grams 
Maximum size: 10000 kilograms

Concentration

7500 ppm to 8000 ppm of Cl2

Design

PPE, CTE, PP&ME

Polarity

Normal
SubstrateTitanium sheet / plate as per ASTM B 265 Gr.1
Titanium tube / pipe as per ASTM B 338/337 Gr.1
Titanium expanded mesh as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1

Catalyst

Platinum group precious metal mixed oxides

Application

Disinfection

Replacement

Siemens, Daiki, Mitsubishi, Cumberland, Pepcon, Sespi,

Nippon, Electrichlor, Sal-Chlor & Many more.


  

Electrolyzer for Brine Electrochlorination - UltrAnode.ca

Electrolyzer for Brine Electrochlorination - UltrAnode.ca    Electrolyzer for Brine Electrochlorination - UltrAnode.ca